I got the following error after I finished a cut. The problem was that the z-axis had gone too far done, and when it powered up it was already in contact with the z-axis switch.
Archive for November, 2019
Lasererror: 170 on z-axis for Trotec Speedy 400
Monday, November 18th, 2019Creating a button to dial videoconference address on polycom Group Series
Monday, November 18th, 2019I had been asked to create a one-button solution to dial a videoconference on a polycom group series. The unit was on a mobile cart and did not have a fixed IP.
I used the Polycom Intergrator Manual to get the API command needed:
dial addressbook name
Where name is the unique first name of an entry in the address book. I needed to create a serial connection from the button to the polycom serial cable (part number 2457-63542-001) . I first tried an arduino with a MAX3232C transceiver and DB9 connector, but it could not send the signal required. I switched to a raspberry pi instead and a FTDI usb to serial adapter which worked correctly.
November 2019 Task list
Monday, November 18th, 2019- Bluejeans rollout for dgp carts and crestron panel updates
- Hardware room training session planning
- server updates and restarte